Quantcast
Channel: VMware Communities : All Content - ESXi
Viewing all 8313 articles
Browse latest View live

ESXi Network Interfaces | Host only | Host to Host

$
0
0

Hello forum, this is my first time posting here so please bare with. I have had a trawl through the documentation but I can't seem to find what I am looking for or I am referencing it incorrectly.

 

What I am trying to achieve is to create an NIC on a host which has nothing plugged into it. I want to do this so that I can create another host and do the same. I then want to join these hosts together. The same as in the real as plugging two devices together using a crossover cable. Is this possible?

 

I am running Cisco IOSv which is peering via BGP to my real routers, instead of using a vSwitch I need to use Cisco Nexus L2V as the switch due to some of the features this offers. I need to assign virtual ports to it to plug in the VM's. So a virtual Router on a stick (ROAS) setup.

 

Anyone able to point me in the right direction? Thanks very much.


Install ESXi 6.5 on R730 with Intel X710

$
0
0

Hello All,

 

After install ESXi 6.0 via "VMware-VMvisor-Installer-6.0.0.update02-4192238.x86_64-Dell_Customized-A04" on Dell PowerEdge R730, everything is okay !!!

 

But, if I try to install ESXi 6.5 via "VMware-VMvisor-Installer-6.5.0-4564106.x86_64-Dell_Customized-A00" on Dell PowerEdge R730, my vmnic0 and vmnic1 (Intel X710 DP 10Gb DA/SFP+) are not working !!!

 

Does anybody know the solution ?

Thanks for your reply.

 

 

[root@R730:~] esxcli network nic list

Name    PCI Device    Driver  Admin Status  Link Status  Speed  Duplex  MAC Address        MTU  Description                                          

------  ------------  ------  ------------  -----------  -----  ------  -----------------  ----  ---------------------------------------------------------

vmnic0  0000:01:00.0  i40en  Up            Up          10000  Full    f8:bc:12:05:85:d0  1500  Intel Corporation Ethernet Controller X710 for 10GbE SFP+

vmnic1  0000:01:00.1  i40en  Up            Up          10000  Full    f8:bc:12:05:85:d2  1500  Intel Corporation Ethernet Controller X710 for 10GbE SFP+

vmnic2  0000:0c:00.0  igbn    Up            Down            0  Half    f8:bc:12:05:85:f0  1500  Intel Corporation Gigabit 4P X710/I350 rNDC          

vmnic3  0000:0c:00.1  igbn    Up            Up            1000  Full    f8:bc:12:05:85:f1  1500  Intel Corporation Gigabit 4P X710/I350 rNDC          

vusb0  Pseudo        cdce    Up            Up            100  Full    18:fb:7b:5d:d5:ee  1500  DellTM iDRAC Virtual NIC USB Device              

 

[root@R730:~] esxcli network nic get -n vmnic0

  Advertised Auto Negotiation: false

  Advertised Link Modes: 1000BaseT/Full, 10000BaseT/Full, 10000BaseT/Full, 40000BaseCR4/Full, 40000BaseSR4/Full

  Auto Negotiation: false

  Cable Type:

  Current Message Level: -1

  Driver Info:

        Bus Info: 0000:01:00:0

        Driver: i40en

        Firmware Version: 5.04 0x800024bc 17.5.11

        Version: 1.1.0

  Link Detected: true

  Link Status: Up

  Name: vmnic0

  PHYAddress: 0

  Pause Autonegotiate: false

  Pause RX: false

  Pause TX: false

  Supported Ports:

  Supports Auto Negotiation: false

  Supports Pause: false

  Supports Wakeon: true

  Transceiver:

  Virtual Address: 00:50:56:52:57:61

  Wakeon: MagicPacket(tm)

how to install Mellanox connectx-4 in ESXi 6.7

$
0
0

Hi

I cannot get ESXi 6.7 to install Mellanox ConnectX-4 in ESXi 6.7

I the UI on the ESXi I can see the Mellanox card under manage->hardware.

But it will not show up under NIC or under HBA, not sure where to find it.

If I from the CLI run the command

esxcli hardware pci list

I can also see the ESXi have found the controller correctly.

But as you can see Module ID and Module Name has not been set.

   Module ID: -1

   Module Name: None

 

I use the build in driver in ESXi 6.7 as it should support this controller and I have upgraded it to newest firmware so it fits with HCL

Any way to fix this?

 

0000:87:00.0
   Address: 0000:87:00.0
   Segment: 0x0000
   Bus: 0x87
   Slot: 0x00
   Function: 0x0
   VMkernel Name: vmnic4
   Vendor Name: Mellanox Technologies
   Device Name: MT27700 Family [ConnectX-4]
   Configured Owner: VMkernel
   Current Owner: VMkernel
   Vendor ID: 0x15b3
   Device ID: 0x1013
   SubVendor ID: 0x15b3
   SubDevice ID: 0x0010
   Device Class: 0x0207
   Device Class Name: Infiniband controller
   Programming Interface: 0x00
   Revision ID: 0x00
   Interrupt Line: 0x0b
   IRQ: 255
   Interrupt Vector: 0x00
   PCI Pin: 0x00
   Spawned Bus: 0x00
   Flags: 0x3201
   Module ID: -1
   Module Name: None
   Chassis: 0
   Physical Slot: 2
   Slot Description: RSC-UN4-88 SLOT2 PCI-E X8
   Passthru Capable: true
   Parent Device: PCI 0:128:3:0
   Dependent Device: PCI 0:135:0:0
   Reset Method: Function reset
   FPT Sharable: true

0000:87:00.1
   Address: 0000:87:00.1
   Segment: 0x0000
   Bus: 0x87
   Slot: 0x00
   Function: 0x1
   VMkernel Name: vmnic5
   Vendor Name: Mellanox Technologies
   Device Name: MT27700 Family [ConnectX-4]
   Configured Owner: VMkernel
   Current Owner: VMkernel
   Vendor ID: 0x15b3
   Device ID: 0x1013
   SubVendor ID: 0x15b3
   SubDevice ID: 0x0010
   Device Class: 0x0207
   Device Class Name: Infiniband controller
   Programming Interface: 0x00
   Revision ID: 0x00
   Interrupt Line: 0x0a
   IRQ: 255
   Interrupt Vector: 0x00
   PCI Pin: 0x01
   Spawned Bus: 0x00
   Flags: 0x3201
   Module ID: -1
   Module Name: None
   Chassis: 0
   Physical Slot: 2
   Slot Description: Chassis slot 2; function 1
   Passthru Capable: true
   Parent Device: PCI 0:128:3:0
   Dependent Device: PCI 0:135:0:1
   Reset Method: Function reset
   FPT Sharable: true

Creating NVMe datastore in ESXi 6.7

$
0
0

Hi,

 

I'm just getting started in ESXi so please bear with me if this question appears rather simplistic!

 

I've installed ESXi 6.7 and I have one Centos 7.4 VM running.  I now want to create a datastore using a NVMe device as a backing store  so that multiple VMs can access this datastore (in the same way that  my hard disk datastore is used by multiple VMs).

 

In my ESXi browser window under Host->Manage->Hardware my NVMe device is listed, so ESXi detects my NVMe drive. However in Storage->Adapters I see only vmhba0 and vmhba1. I don't see any NVMe adapters. Thus when I try to create a new datastore, it can't find any NVMe adapter.

 

What do I have to do create a NVMe adapter?

 

thanks for your help

NFS 4.1 export mounts as read-only (RECLAIM_COMPLETE FS failed)

$
0
0

Seems to be the case that when mounting NFS 4.1 using Windows Server 2012 R2 as the endpoint people are getting the following error:

 

2015-08-15T13:55:59.460Z cpu0:34075 opID=e5c595d5)NFS41: NFS41_VSIMountSet:402: Mount server: 172.20.10.14, port: 2049, path: normal, label: nfs, security: 1 user: , options: <none>

2015-08-15T13:55:59.460Z cpu0:34075 opID=e5c595d5)StorageApdHandler: 982: APD Handle  Created with lock[StorageApd-0x43059cff25c0]

2015-08-15T13:55:59.461Z cpu1:33347)NFS41: NFS41ProcessClusterProbeResult:3865: Reclaiming state, cluster 0x43059cff3780 [4]

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSCompleteMount:3582: Lease time: 120

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSCompleteMount:3583: Max read xfer size: 0x3fc00

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSCompleteMount:3584: Max write xfer size: 0x3fc00

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSCompleteMount:3585: Max file size: 0xfffffff0000

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSCompleteMount:3586: Max file name: 255

2015-08-15T13:55:59.462Z cpu0:34075 opID=e5c595d5)WARNING: NFS41: NFS41FSCompleteMount:3591: The max file name size (255) of file system is larger than that of FSS (128)

2015-08-15T13:55:59.463Z cpu0:34075 opID=e5c595d5)WARNING: NFS41: NFS41FSCompleteMount:3601: RECLAIM_COMPLETE FS failed: Failure; forcing read-only operation

2015-08-15T13:55:59.463Z cpu0:34075 opID=e5c595d5)NFS41: NFS41FSAPDNotify:5651: Restored connection to the server 172.20.10.14 mount point nfs, mounted as 907c6b39-acb49d79-0000-000000000000 ("normal")

2015-08-15T13:55:59.463Z cpu0:34075 opID=e5c595d5)NFS41: NFS41_VSIMountSet:414: nfs mounted successfully

 

A snippet from the NFS 4.1 RFC has this to say about RECLAIM_COMPLETE  (RFC 5661 - NFS Version 4 Minor Version 1 - Page 567)

Whenever a client establishes a new client ID and before it does the

  first non-reclaim operation that obtains a lock, it MUST send a

  RECLAIM_COMPLETE with rca_one_fs set to FALSE, even if there are no

  locks to reclaim. If non-reclaim locking operations are done before

  the RECLAIM_COMPLETE, an NFS4ERR_GRACE error will be returned.

 

 

  Similarly, when the client accesses a file system on a new server,

  before it sends the first non-reclaim operation that obtains a lock

  on this new server, it MUST send a RECLAIM_COMPLETE with rca_one_fs

  set to TRUE and current filehandle within that file system, even if

  there are no locks to reclaim. If non-reclaim locking operations are

  done on that file system before the RECLAIM_COMPLETE, an

  NFS4ERR_GRACE error will be returned.


I ran a capture during the mount which shows that the ESXi host sent a RECLAIM_COMPLETE with rca_one_fs set to FALSE, later it sends another RECLAIM_COMPLETE with rca_one_fs set to TRUE and a filehandle specified.  This looks like the correct behavior.

first-reclaim.png  second-reclaim.png

Last of all, back in the RFC is this little tidbit:

RECLAIM_COMPLETE should only be done once for each server instance or

  occasion of the transition of a file system. If it is done a second

  time, the error NFS4ERR_COMPLETE_ALREADY will result. Note that

  because of the session feature's retry protection, retries of

  COMPOUND requests containing RECLAIM_COMPLETE operation will not

  result in this error.

 

The screenshots also appear to show that both RECLAIM_COMPLETE operations are COMPOUND, so it seems to me that ESXi is doing what it is supposed to do, but the NFS server is sending back an error when it shouldn't which is causing the host to fall back to read-only access mode.

 

Any input from the wider community?  Happy to be stood corrected! 

best practice to Update ESXi6 in CLuster

$
0
0

i have two host with Vcenter cluster config with DRS and HA , and i would like upgrade the two hypervisor ,

How to easily update my VMware Hypervisor to from ESXI 6.0.0i 6.0 Update 2 what's the best practice ,

 

 

thank you .

esxi 6.7 network configuration

$
0
0

I completed installation of Vmware Esxi 6.5 on my server HP DL380 g9 with 4 network adapters so I have Three port group.
1.Managment network.
2.Lanzone
3.Wanzone
...........
Lanzone has its own virtual switch called LanvSwitch
Wanzone has its own virtual switch named WanvSwitch
..............
LanvSwitch has one uplink mapped to vmnic1
WanvSwitch has one uplink mapped to vmnic2
..............
All ports of the server connected to one physical switch ...Dlink
..............

Virtual machine of Sophos has many network adapters.
I made adapter 1 to LanZone portgroup. And Adapter 2 to WanZone portgroup.
..........
I can see preconfigured ips in sophos. I tried to reach all from the physical network of switch (Dlink) mentioned above but no success.

Did you observe any mis-configured issue above?

I could not access the virtual machine from my physical network, why ?

How do I get a license for ESXi 4.1?

$
0
0

Latest version of ESXi is not compatible with my old Dell T7400. 4.1 installs and runs, but the license number I got for my 6.7 download won't work with my 4.1 install.

Is it possible to still get a license for 4.1?

Thanks,

Chris


NFS Storage , ESXi 6.7

$
0
0

hi community,

 

Am I able to do this.

 

I have a spear server and wanted to have 8 SSD drives in a RAID 5 , and have a quad network card installed. can I attach the dell blade servers in a FX2s chassis directly to the other server for storage for eg like a iSCSI. would that work over the ethernet so I can directly connect them together without a switch or a router, and use the RAID 5 storage on the other server to install VMs onto.

 

Matt

upgrading of esxi host

$
0
0

i have a few ESXi host that is on version 5.1.

can i upgrade them straight to 6.5 or in stages, from 5.1 to 5.5 then to 6.5 ?

will there be any issue if i upgrade straight to version 6.5?

RDM mapped to Windows 2008 Server guest "file or directory is corrupted and unreadable"

$
0
0

I wanted to move an NTFS-formatted 4TB SATA drive from a Lubuntu machine to my Windows Server 2008 VM (running on an ESXI 6.5 host - Dell Optiplex 3010). I installed the drive in the server, then mapped it as as RDM. The Windows VM can see the drive, but can't read the content (it was about 80% full of files) - I get "the file or directory is corrupted and unreadable". Any ideas??

Installing ESXi - fatal error 6 (Buffer too small)

$
0
0

I tried to install the evaluation version of VMware ESXi 5 server and I finished pretty fast. The only thing I could see on the screen was:

 

Loading /tboot.b00

Loading /b.b00

Loading /useropts.gz

Loading /k.b00

Loading /a.b00

Loading /ata-pata.v00

Loading /ata-pata.v01

Loading /ata-pata.v02

Loading /ata-pata.v03

Loading /ata-pata.v04

Loading /ata-pata.v05

Error loading /ata-pata.v05

Fatal error: 6 (Buffer too small)

 

Could anyone please help me a bit? I don't know at all, what's going on and how should I continue with the installation.

 

Thanks.

command to find machines not in autostart

$
0
0

Is there a command I can run via SSH to find machines that are set to manual startup?  I'd like to monitor this and was curious what the command would be.  I'm currently messing around with vim-cmd.

 

Thanks!

ESXi 6.7 - OVF Export Fails on VMDK export

$
0
0

I just installed VMware ESXi on a Dell R620 to test with. I have an opensuse 42.3 Linux guest VM that is powered off. When I go to export as OVF I can fetch the .ovf file, but it fails to fetch the associated VMDK. In Google Chrome I get "Failed - Network Error." When I use Firefox it fetches about 80-90MB of the VMDK and then stops. There is no error shown. On the ESXi host, it shows the request for the export but does not log any actual error.

 

I tried downloading the VMDK via the datastore browser but that didn't fetch the actual vmdk.

upgrade vds 5.5 to 6.5

$
0
0

any issues upgrading vds from 5.5 to 6.5? Can i do that during business hours?


ESXi 6.5 10 GB connection with EMC iSCSI storage

$
0
0

Hi all,

 

We have one CISCO c240 rack mount server and one EMC VNX3200.

 

EMC VNX3200 has four 10 Gb/s Ethernet Ports. Servers has four 1GbE ports. We want to setup 10 GB connectivity for the iSCSI storage. Can any one tell us, if we procure  and install 10GB port on server, can we directly connect server to storage 10GB connection for iSCSI storage. EMC VNX3200 is the iSCSI storage.

 

Do we need to buy any extra switch to connect server and storage 10GB connection ?

 

Regards,

Using a USB drive to backup VM in ESXi 6.5

$
0
0

Hi all!

 

I'm using an ESXi 6.5 with some virtual machines to conduct some use case at university. I do not have a full structure nor the ESXi is a production machine (this means I can stop the service as often and as long as I need).

 

The problem is: I would like to backup the VMs. I tried to export the VMs in OVA format but I always got a network error, so I decide to back them up using an attached USB drive (an external HD from Seagate). To accomplish that, I enabled SSH and SSH to the host, but I could not see the USB HD nor any device like /dev/sd*

 

Can you help me?

 

Thanks!

Alexandre

Maas DNS not working on Vmware ESXi

$
0
0

Hi,

I have a MAAS setup that works perfectly fine as a VM on Vmware Workstation. When I do a nslookup on a node known by MAAS, the resolution is successfull (with maas node IP in resolv.conf, followed by "search maas").

But when I migrate this exact same Maas setup into Vmware ESXi, I have systematically a "NXDOMAIN" error. A nmap performed from another vm running on ESXi give me this :

Nmap scan report for maas.maas (192.168.2.2)
Host is up (0.000092s latency).
Not shown: 993 closed ports
PORT STATE SERVICE
22/tcp open ssh
53/tcp open domain
80/tcp open http
3128/tcp open squid-http
3260/tcp open iscsi
7911/tcp open unknown
8000/tcp open http-alt

Nmap done: 1 IP address (1 host up) scanned in 0.03 seconds

So, my dns service is running. I can't figure out what is going on !

Diskpart 2003 server C partition

$
0
0

The posts and instructions I have read regarding increasing the provisioned size of a virtual disk say I have to shut down the virtual server the disk is on, add the disk to another virtual server, change the provisioned size then shutdown that virtual server, remove the added disk, and re-add the disk to the original virtual server then run diskpart on the original virtual server to extend the partition.

 

Can I just change the provisioned size on the powered on virtual server in edit settings then run diskpart on that virtual server and reboot to extend the partition size?

 

Thanks

Intel NUC7 i7 DNHE & VMWare 6.5, 6.7: Installation hangs

$
0
0

Hi all,

 

I just got a brand new Intel NUC7.

 

When installing the device, the procedures always hangs (or: seems to hang) at "initializing storage stack".

 

I have done some searching but I didn't find any strategy on how to handle this.

 

For starters, I was also trying to get a more verbose output during installation (like what exactly is stuck at that message, see above) etc., but also I didn't find any boot time option for the installer to get a more detailled output.

 

Configuration is:

- 32GB RAM

- Samsung 960 Pro 512 M.2

- Seagate 2TB HDD

 

Any help welcome, since without ESXi on that system I would need to send it back again ;(

 

Cheers!

Viewing all 8313 articles
Browse latest View live